Liquid / Powdered Detergents

Provides maximum hydroxide alkalinity.

VIGOR

VIGOR is a heavy duty liquid alkaline pipeline and bulk tank cleaner containing sodium hydroxide, anti-re-deposition polymers, water softening agents, stabilizing and chlorinating agent. VIGOR is recommended for applications where heavy butterfat and oily soils are encountered. VIGOR is a concentrated heavy-duty pipeline and bulk tank cleaner developed to provide maximum hydroxide alkalinity along with dispersing agents, water softeners, wetting agents and iron inhibiting ingredients.

More Details

Vigor is a member of the Elite Products program. Other products included in the Vanco Elite Product program is VanGuard, Vantage, Vigilant, Vision, VanQuarter, Vanish, Vibrant, Venom, Vigor II Powder, and Vanco’s Premium Dairy Wipes.

VIGOR PIPELINE CLEANING RATIO:
Water Hardness Oz. of VIGOR to Water
0 to 14 Grains 1 Oz. to 4 Gallons of Water
15 to 24 Grains 1 Oz. to 3 Gallons of Water
25 to 39 Grains 1 Oz. to 2 Gallons of Water

GENERAL INSTRUCTIONS
Upon completion of milking, thoroughly flush entire pipeline system with warm water. (100°F-110°F/38°C-43°C) Do NOT recycle rinse water. Once rinse water runs clean and clear, add the appropriate amount of VIGOR liquid CIP cleaner to the HOT water. Cycle cleaning solution through the entire system for 8-10 minutes. Flush entire pipeline thoroughly with warm water. (100°F-110°F/38°C-43°C) Do NOT recycle rinse water. Acid rinse using a VANCO acid. Sanitize prior to milking according to local Health Department regulations. More VIGOR may be required for larger systems.

FOR BEST RESULTS
Start wash with water temperature at 165°F/74°C. If using cooler water, more VIGOR liquid CIP cleaner will be necessary. Stop wash when the water temperature falls below 105°F/41°C.

VANISH

VANISH is a concentrated, heavy duty bulk tank and pipeline cleaner. Developed to provide maximum hydroxide alkalinity along with dispersing agents, water softeners, wetting agents and Iron inhibiting ingredients. VANISH is an economical alternative to most pipeline cleaners due to its high dilution rates.

VANISH is a member of the Elite Products program. Other products included in the Vanco Elite Product program is VanGuard, Vantage, Vigilant, Vision, VanQuarter, Vigor, Vibrant, Venom, Vigor II Powder, and Vanco’s Premium Dairy Wipes.

More Details

VANISH PIPELINE CLEANING RATIO:
Water Hardness Oz. of VANISH to Water
0 to 14 Grains 1 Oz. to 9 Gallons of Water
15 to 24 Grains 1 Oz. to 6 Gallons of Water
25 to 39 Grains 1 Oz. to 4 Gallons of Water

GENERAL INSTRUCTIONS
Upon completion of milking, thoroughly flush entire pipeline system with warm water. (100°F-110°F/38°C-43°C) Do NOT recycle rinse water. Once rinse water runs clean and clear, add the appropriate amount of VANISH liquid CIP cleaner to the HOT water. Cycle cleaning solution through the entire system for 8-10 minutes. Flush entire pipeline thoroughly with warm water. (100°F-110°F/38°C-43°C) Do NOT recycle rinse water. Acid rinse using a VANCO acid. Sanitize prior to milking according to local Health Department regulations. More VANISH may be required for larger systems.

FOR BEST RESULTS
Start wash with water temperature at 165°F/74°C. If using cooler water, more VANISH liquid CIP cleaner will be necessary. Stop wash when the water temperature falls below 105°F/41°C.

VIGOR II

VIGOR II is a chlorinated alkaline heavy-duty C.I.P. and bulk tank powder cleaner, formulated with a blend of alkaline hydroxide builders, water softening agents, dispersants and chlorinating compound. VIGOR II will provide excellent butterfat saponification and milk protein soil detergency.

VIGOR II is a member of the Elite Products program. Other products included in the Vanco Elite Product program is VanGuard, Vantage, Vigilant, Vision, VanQuarter, Vigor, Vanish, Vibrant, Venom, and Vanco’s Premium Dairy Wipes.

More Details

VIGOR PIPELINE CLEANING RATIO:
Water Hardness Oz. of VIGOR to Water
0 to 20 Grains 1 Oz. to 3 Gallons of Water
21 to 30 Grains 1 Oz. to 2 Gallons of Water
31 to 40 Grains ¾ Oz. to 1 Gallons of Water

GENERAL INSTRUCTIONS
Upon completion of milking, thoroughly flush entire pipeline system with warm water. (100°F-110°F/38°C-43°C) Do NOT recycle rinse water. Once rinse water runs clean and clear, add the appropriate amount of VIGOR II Powder CIP cleaner to the HOT water. Cycle cleaning solution through the entire system for 8-10 minutes. Flush entire pipeline thoroughly with warm water. (100°F-110°F/38°C-43°C) Do NOT recycle rinse water. Acid rinse using a VANCO acid. Sanitize prior to milking according to local Health Department regulations. More VIGOR II may be required for larger systems.

FOR BEST RESULTS
Start wash with water temperature at 165°F/74°C. If using cooler water, more VIGOR II Powder CIP cleaner will be necessary. Stop wash when the water temperature falls below 105°F/41°C.

Use 1 ounce of VIGOR II Powder C.I.P. cleaner to 3gallons of water at 165°F/74°C. When used in automatic systems, VIGOR II Powder must be premixed and dissolved in water.

Once bulk tank is emptied, thoroughly flush entire tank with warm water. (100°F-110°F/38°C-43°C) Using the appropriate ratio of VIGOR II powder CIP cleaner, spray tank for 10-15 minutes. Thoroughly rinse tank with warm water. (100°F-110°F/38°C-43°C) Acid rinse using a VANCO acid. Sanitize prior to milking according to local Health Department regulations.